Fujitsu ARTG30LHTDP Ducted Air Conditioner
$0.00
Fujitsu 8.5kW 1 Phase Ducted Unit
Category Ducted Air Conditioner Systems
- Safe & Secure Check-Out
- Brisbane & Gold Coast Pick-Up
- Quality Guaranteed
Fujitsu 8.5kW 1 Phase Ducted Unit
Indoor | ARTG30LHTDP | ||
Outdoor | AOTG30LBTA | ||
Operation Type | Reverse Cycle | ||
Power Source | V / ø / Hz | 240 / 1 / 50 | |
Capacity (Min – Max) | Cooling | kW | 8.50 (2.80 – 10.00) |
Heating | kW | 10.00 (2.70 – 11.20) | |
Input Power | Cooling | kW | 2.65 (Max 4.06) |
Heating | kW | 2.70 (Max 4.06) | |
Rating | Cooling | EER | 3.21 |
AEER | 3.25 | ||
Heating | COP | 3.7 | |
ACOP | 3.7 | ||
Running Current | Cooling | A | 11.1 |
Heating | A | 11.3 | |
Moisture Removal | L / Hr | 2.3 | |
Noise Level | Indoor Sound Pressure (High / Quiet) | dBA | 37 / 29 |
Outdoor Sound Pressure | dBA | 53 | |
Outdoor Sound Power | dBA | 69 | |
Static Pressure Range | PA | 30 to 200 | |
Air Circulation (Indoor – High Fan) | L / s | 472 | |
Dimensions HxWxD | Indoor | mm | 300 x 1000 x 700 |
Outdoor | mm | 830 x 900 x 330 | |
Weight | Indoor | kg | 36 |
Outdoor | kg | 61 | |
Piping Connections (Liquid / Suction) | mm | ø9.52 / ø15.88 | |
Max. Pipe Length (Precharged Length) | m | 50 (20) | |
Max Height Difference | m | 30 | |
Operation Range | Cooling | °CDB | -10 to 46 |
Heating | °CDB | -15 to 24 | |
Refrigerant | R410A |
Category Ducted Air Conditioner Systems